267 research outputs found

    How Should Governments Address High Levels of Natural Radiation and Radon--Lessons from the Chernobyl Nuclear Accident and Ramsar, Iran

    Get PDF
    The authors discuss the high levels of natural background radiation in Ramsar, Iran, and offer data indicating that this has had little effect on the health of Ramsar\u27s inhabitants. The authors then examine the implications their research could have for public health policy

    Hygrothermal durability of bond in FRP-strengthened masonry

    Get PDF
    Fiber reinforced polymers (FRPs) are accepted as an efficient material for external strengthening of masonry structures. Previous researches have shown that the bond between FRP and the substrate plays an important role in the effectiveness of this strengthening technique. Extensive investigations have been devoted to the characterization of the short-term bond behavior, while its durability and long-term performance requires further studies. In this regard, a full experimental program for investigating the environmental durability of bond in FRP-strengthened masonry is crucial for understanding the degrading mechanisms. This paper presents the results of an experimental program aimed at investigating the hygrothermal durability of bond in FRP-strengthened bricks. Accelerated ageing tests were performed on the FRP-strengthened brick elements and the bond degradation was periodically investigated by visual inspection and by conventional single-lap shear bond tests. The changes in the properties of material constituents have also been monitored. The obtained results are presented and critically discussed.This work was developed within the framework of the RILEM Technical Committee "223-MSC: Masonry Strengthening with Composite Materials". The financial support from the project FP7-ENV-2009-1-244123-NIKER of the 7th Framework Program of the European Commission is gratefully acknowledged. The first author also acknowledges the financial support of the Portuguese Science Foundation (Fundacao de Ciencia e Tecnologia, FCT), through grant SFRH/BD/80697/2011

    Debonding damage analysis in composite-masonry strengthening systems with polymer- and mortar-based matrix by means of the acoustic emission technique

    Get PDF
    Different types of strengthening systems, based on fiber reinforced materials, are under investigation for external strengthening of historic masonry structures. A full characterization of the bond behavior and of the short- and long-term failure mechanisms is crucial to ensure effective design, compatibility with the historic substrate and durability of the strengthening solution. Therein, non-destructive techniques are essential for bond characterization, durability assessment and on-site condition monitoring. In this paper, the acoustic emission (AE) technique is evaluated for debonding characterization and localization on fiber reinforced polymer (FRP) and steel reinforced grout-strengthened clay bricks. Both types of strengthening systems are subjected to accelerated ageing tests under thermal cycles and to single-lap shear bond tests. During the reported experimental campaign, AE data from the accelerated ageing tests demonstrated the thermal incompatibility between brick and epoxy-bonded FRP composites, and debonding damage was successfully detected, characterized and located. In addition, a qualitative comparison is made with digital image correlation and infrared thermography, in view of efficient on-site debonding detection.The authors acknowledge the financial support of the Research Foundation-Flanders (FWO) for the mobility grant offered to Els Verstrynge.info:eu-repo/semantics/publishedVersio

    Moisture effects on the bond strength of FRP-masonry elements

    Get PDF
    Moisture exposure has been observed to be one of the degrading environmental agents which affects the durability of the FRP-strengthened elements by changing the constituent material or bond properties. This paper presents the experimental investigation on the effects of moisture on the pull-off bond strength of GFRP-strengthened brick specimens. The specimens have been prepared following the wet lay-up procedure and exposed to constant moisture level of 100% R.H. at 23̊C for 8 weeks. The degradation in the bond performance has been investigated by performing pull-off tests on the conditioned specimens after 4 and 8 weeks of exposure. The reversibility of the bond degradation has been also studied by storing some specimens in the laboratory conditions for 1 week after conditioning and before performing the pull-off tests. Comparative analysis has been performed and the main results are presented and discussed

    On-line hydraulic state prediction for water distribution systems

    Get PDF
    World Environmental and Water Resources Congress 2009: Great Rivers Proceedings of World Environmental and Water Resources Congress 2009 May 17–21, 2009 Kansas City, MissouriThis paper describes and demonstrates a method for on‐line hydraulic state prediction in urban water networks. The proposed method uses a Predictor‐Corrector (PC) approach in which a statistical data‐driven algorithm is applied to estimate future water demands, while near real‐time field measurements are used to correct (i.e., calibrate) these predicted values on‐line. The calibration problem is solved using a modified Least Squares (LS) fit method. The objective function is the minimization of the least‐squares of the differences between predicted and measured hydraulic parameters (i.e., pressure and flow rates at several system locations), with the decision variables being the consumers' water demands. The a‐priori estimation (i.e., prediction) of the values of the decision variables, which improves through experience, facilitates a better convergence of the calibration model and provides adequate information on the system's hydraulic state for real time optimization. The proposed methodology is demonstrated on a prototypical municipal water distribution system

    The need for national diagnostic reference levels: Entrance surface dose measurement in intraoral radiography

    Get PDF
    Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection (ICRP) recommendations, the selection of a diagnostic reference level (DRL) should be specific to a country or region. Critical organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low as reasonably achievable. To assist the development of DRLs for intraoral radiography, a National Radiation Protection Department-sponsored pilot study was carried out. Materials and Methods: Thermoluminescent dosimetry (TLD) is widely acknowledged to be the recommended method for measuring entrance surface doses (ESD). In this study, ESD was measured using LiF thermoluminescent dosimeters (TLD-100) on the skin (either mandibular or maxillary arcs) of 40 patients. Three TLD chips were placed on the skin of each patient. The doses were averaged for each radiography and mean ESD of all patients calculated. Results: The mean ± SD entrance surface dose at the center of the beam on the patients' skin in intraoral radiography was 1.173 ± 0.606 mGy (ranged from 0.01 to 0.40 mGy). The mean ESD for male and female patients were 1.380 ± 0.823, and 1.004 ± 0.258 respectively. No statistically significant difference was found between these means. Despite its necessity, in national level, there is no published data on the diagnostic reference levels for intraoral radiography. However, the results obtained in this study are lower than those reported by investigators in other countries. Conclusion: In IR Iran, due to lack of large scale studies, no diagnostic reference levels have been set for X-ray diagnostic procedures. Due to lack of national diagnostic reference levels, it is not possible to clarify whether in intraoral radiographies any dose reduction techniques are needed. We intend to perform similar nationwide studies to set the diagnostic reference level for intraoal radio graphy

    Entrance surface dose measurement on the thyroid gland in orthopantomography: The need for optimization

    Get PDF
    Background: The anatomic position and proven radiosensitivity of the thyroid make it an organ of concern in dental X-ray examinations. A National Radiation Protection Department (NRPD)-sponsored pilot study carried out in the Dental Radiology Department of RUMS., to assess if the radiation dose in panoramic radiographies could be reduced without significant impairment of the subjective image quality. Materials and Methods: Thermoluminescent dosimetry (TLD) is widely acknowledged to be the recommended method for measuring entrance surface doses (ESD). In this study, ESD was measured using LiF thermoluminescent dosimeters (TLD-100) on the thyroid of 40 patients who had referred to the School of Dentistry, Rafsanjan University of Medical Sciences. Patients were not exposed to any additional radiation and the radiographs were used for diagnostic purposes. TLDs were calibrated with radiation energies similar to those commonly used in orthopantomography. Results: The overall mean ESD on the thyroid in orthopantomography was 0.071 ± 0.012 mGy (ranged from 0.01 to 0.40 mGy). The mean ESD for radiographies performed with 66 kVp (20 patients) and 68 kVp (20 patients) were 0.072 ± 0.019, and 0.070 ± 0.016 respectively. No statistically significant difference was found between these means. Conclusions: The measured surface doses in our study are inconsistent with the only one already reported about the same experiment. However, due to lack of national diagnostic reference levels for orthopantomography, it is not clear whether in case of the PM 2002 CC unit used in this experiment, reducing the radiation dose to a level that still keeps a diagnostically acceptable image quality is necessary

    FRP-to-masonry bond durability assessment with infrared thermography method

    Get PDF
    The bond behavior between FRP composites and masonry substrate plays an important role in the performance of externally bonded reinforced masonry structures. Therefore, monitoring the bond quality during the application and subsequent service life of a structure is of crucial importance for execution control and structural health monitoring. The bond quality can change during the service life of the structure due to environmental conditions. Local detachments may occur at the FRP/substrate interface, affecting the bond performance to a large extent. Therefore, the use of expedite and efficient non-destructive techniques for assessment of the bond quality and monitoring FRP delamination is of much interest. Active infrared thermography (IR) technique was used in this study for assessing the bond quality in environmentally degraded FRP-strengthened masonry elements. The applicability and accuracy of the adopted method was initially validated by localization and size quantification of artificially embedded defects in FRP-strengthened brick specimens. Then, the method was used for investigating the appearance and progression of FRP delaminations due to environmental conditions. GFRP-strengthened brick specimens were exposed to accelerated hygrothermal ageing tests and inspected periodically with the IR camera. The results showed environmental exposure may produce large progressive FRP delaminations.Fundação para a Ciência e Tecnologi

    Joint Optimal Design and Operation of Hybrid Energy Storage Systems

    Get PDF
    The wide range of performance characteristics of storage technologies motivates the use of a hybrid energy storage systems (HESS) that combines the best features of multiple technologies. However, HESS design is complex, in that it involves the choice of storage technologies, the sizing of each storage element, and deciding when to charge and discharge each underlying storage element (the operating strategy.We formulate the problem of jointly optimizing the sizing and the operating strategy of an HESS that can be used for a large class of applications and storage technologies. Instead of a single set of storage element sizes, our approach determines the Pareto-optimal frontier of the sizes of the storage elements along with the corresponding optimal operating strategy. Thus, as long as the performance objective of a storage application (such as an off-grid microgrid) can be expressed as a linear combination of the underlying storage sizes, the optimal vector of storage sizes falls somewhere on this frontier. We present two case studies to illustrate our approach, demonstrating that a single storage technology is sometimes inadequate to meet application requirements, unlike an HESS designed using our approach. We also find simple, near-optimal, and practical operating strategies for these case studies, which allows us to gain several new engineering insights
    corecore